The selectivity is determined by L1/C4 and is primarily dependent on the standard suppression coil L1. Gain for operating the relay is provided by T1. The amplified signal is smoothed by C6 and provides the voltage necessary to cause T2 to conduct and energize the relay. The voltage divider formed by P1, R1 and R2 provides a bias voltage for T1 in order to increase the sensitivity of the receiver. This also allows the relay to be energized without a received signal. D1ensures that C5 does not become charged and prevents T1 from conducting even more.
The operation of the circuit is based on the fact that the incoming signal is sufficiently strong to overcome the hysteresis of the relay. Once the signal is no longer present, the relay must naturally again release. To be honest, it must be noted that the simple design of this circuit has the disadvantage that its sensitivity may be somewhat inadequate, depending on household circumstances. One possible solution is to reduce the frequency of the transmitter to the region between 95 and 125 kHz. The values of C1, C2 and C4 will then have to be modified to match, so this is something for readers who like to experiment.
Do not forget that just as with the transmitter, the entire circuit (once it has been switched on, of course) is connected to the mains potential. Power for the transistor stage and the relay is taken directly from the mains voltage using a capacitive voltage divider; R5 is only necessary to limit the current through the diodes to a safe value on switch-on. Rectification is provided by diodes D4–D7 and filtering by C7. The impedance of C8 is low enough to provide sufficient current. The no-load voltage (when T2 is not conducting and the relay is not activated) is limited by zener diode D3.
R6 and R7 discharge C8 immediately after the circuit is disconnected from the mains, in order to prevent any dangerous voltage from remaining on the input terminals. Connections A and B are provided for test purposes and also allow something other than the relay to be energised (but keep in mind that the circuit is electrically connected to the mains network!). The pinout of the relay is standard, so a type other than that shown in the components list can also be used, as long as you make sure that the operating voltage is 24 V and the operating current does not exceed 28mA.
Resistors:
- R1 = 1MΩ5
- R2 = 220kΩ
- R3 = 39kΩ
- R4 = 6kΩ8
- R5 = 220Ω
- R6,R7 = 470kΩ
- P1 = 10MΩ preset
- C1 = 22nF 275VAC Class X2, lead pitch 15mm
- C2 = 22nF, lead pitch 5 mm
- C3 = 220pF
- C4 = 2nF2, lead pitch 5mm
- C5 = 680pF
- C6 = 100nF, lead pitch 5 mm
- C7 = 100µF 40V radial
- C8 = 330nF 275VAC, Class X2, lead pitch 22.5mm or 27.5mm
- L1 = 470µH
- D1 = BAT85
- D2 = 1N4148
- D3 = zener diode 24V 1.3W
- D4-D7 = 1N4007
- T1 = BC557B
- T2 = BC547B
- K1,K2 = 2-way PCB header, lead pitch 7.5 mm
- Tr1 = 5:5 turns 1mm dia. isolated wire on N30 ring core 16x6.3 mm, B64290L45X830 EPCOS
- Re1 = PCB relay, 1 c/o contact, 8A 24V 1200Ω,